Facebook Pixel

Nidec-Embraco NT2210UV2 208-230V1Ph R290 1 1/4Hp Comp

Special Price $737.39 Regular Price $818.50
In stock
SKU
NT2210UV2
The Nidec-Embraco NT2210UV2 1-1/4HP Compressor 208230 V/1PH is a temperature compression component that is used to circulate R290 refrigerant in HVAC systems. It is installed in condensing units, and it compresses low-pressure vapor into a high-pressure state so that heat can be transferred through the system. This compressor refrigeration cycle propels refrigerant circulation between the evaporator and the condenser that assists in effective cooling operation and smooth temperature regulation. Its application assists in keeping the system pressure in check, constant operation and dependable cooling in the commercial and light industrial processes.
Manufacturer:
https://www.partshnc.com/media/catalog/product/n/t/nt2210uv2.jpg
Manufacturer Name: Nidec-Embraco
Product Number: NT2210UV2
OEM Part Number: NT2210UV2
Product Description: 208-230V1ph R290 1 1/4Hp Comp
Weight:42.05lbs/19073.54g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Nidec-Embraco NT2210UV2 208-230V1Ph R290 1 1/4Hp Comp
Your Rating
Customer Questions
What maintenance is required for the Nidec-Embraco NT2210UV2 Compressor?

Regularly inspect the compressor for oil levels, refrigerant leaks, and unusual noises. Keep surrounding vents and coils clean to ensure proper airflow. Ensure proper electrical connections and avoid overloading to maintain efficiency and prevent overheating.

What are common issues with the Nidec-Embraco NT2210UV2 Compressor?

  • Overheating or tripping of overload protector.
  • Inconsistent cooling performance.
  • Refrigerant leaks or pressure irregularities.
  • Unusual humming or vibration during operation.

Installation Steps

Step1: Turn off power and recover the refrigerant from the system completely.

Step2: Disconnect electrical wiring and mark all terminal connections for reference.

Step3: Remove refrigerant lines and unbolt the old compressor from its mount.

Step4: Install the new compressor, secure it to the base, and braze suction and discharge lines properly.

Step5: Replace the filter drier and pull a deep vacuum to remove moisture and air.

Step6: Recharge with R290 refrigerant to specification and test for leaks, proper pressure, and safe operation.