Carrier HK06MB020 Dual Pressure Switch -0.75"WC/-0.30" WC

Special Price $66.39 Regular Price $73.80
In stock
SKU
HK06MB020
The Carrier HK06MB020 Dual Pressure Switch is a part used for controlling pressure in a HVAC systems. It is a dual pressure switch that consists of two separate pressure sensing mechanisms, high pressure and low pressure. These elements are coupled to the refrigerant lines of the system in question. If the pressure of the system is outside the set limits, the switch turns on or off the electrical contacts to initiate corresponding actions in the system’s control circuit. For example, the high-pressure sensor may indicate that the pressure is too high, and directly stop the compression to avoid something going wrong.
https://www.partshnc.com/media/catalog/product/h/k/hk06mb020_1.jpg

Specifications

  • Type: Dual Pressure Switch
    Manufacturer Name: Carrier
    Product Number: HK06MB020
    OEM Part Number: HK06MB020
    Product Description: Dual Pressure Switch
    Weight:0.21lbs/95.25g

    Choose the best HVAC equipment parts and supplies from PartsHnC!

    • Same Day Shipping

    • Best Quality And Best Price

    • Wide Range of Inventory

    • Best Customer Service

    Have More Questions or Need Help to Place The Order?
    Reach us at (866)773-0907 or [email protected]

    Write Your Own Review
    You're reviewing:Carrier HK06MB020 Dual Pressure Switch -0.75"WC/-0.30" WC
    Your Rating
    Customer Questions
    What maintenance is required for the Carrier HK06MB020 Dual Pressure Switch?

    Inspect pressure ports and tubing regularly for blockages or moisture buildup. Clean contacts and ensure secure electrical connections. Verify calibration during routine HVAC service. Proper maintenance ensures accurate pressure sensing, stable operation, and safe system performance.

    What are common issues with the Carrier HK06MB020 Dual Pressure Switch?

    • Erratic switching due to clogged pressure ports.
    • Failure to actuate at correct differential pressure.
    • Intermittent operation from worn electrical contacts.
    • Moisture ingress affecting sensing accuracy.
    • Air tubing leaks causing false readings.

    Installation Steps

    Step 1: Turn off power and gas supply; verify system is isolated before starting.

    Step 2: Remove access panel and locate pressure switch and tubing connections.

    Step 3: Disconnect wires and hoses, noting positions, then remove old switch.

    Step 4: Mount new switch, reconnect tubing and wiring as labeled.

    Step 5: Secure fittings and ensure tubing is free of cracks or blockages.

    Step 6: Restore power, test furnace operation, and check pressure switch response.

    Step 7: Observe startup for leaks or cycling issues; shut down if issues appear.