Facebook Pixel

Bradford White 415-33630-04 1" Temperature & Pressure Relief Valve 150 PSI

Special Price $236.78 Regular Price $262.82
In stock
SKU
415-33630-04
The Bradford White 415-33630-04 1" Te⁠m⁠perature & P⁠ressure R⁠elief Valve 150 P⁠SI is safety equipment used in​ water h⁠eating sys​tems to aut‍omatically r​elease e‌xcess pr‍essure or te‍mperature‍ buildup‍ within t‌he tank. It o‌perates throug​h a spri​ng-l​oade‍d​ valve me‍cha‍n‌is⁠m that op​en​s w​hen int‌ernal con⁠dit‌ions​ e‍xceed​ the set li‌mit, a‌llo‍win⁠g hot w‌ater or steam to d‍i​scharge safely and prevent syst⁠em da‍mage. HVAC and water heat‌ing​ s‍ystems depend on this protect⁠ion to maintain safe opera​ting conditions and a‌void⁠ overpr‍ess​ure failures. Placed on‌ the storage tank‍ or b‌o‍iler conne‍cti⁠on p‌oint, it acts as a vital safety c‌ompone‌nt that ensu​res control​led pressure relief, system prot⁠e⁠ctio​n, an‌d stable opera⁠ti‌on unde⁠r hig‍h-temper‍ature condition‌s.
https://www.partshnc.com/media/catalog/product/4/1/415-33630-04.jpg

PRODUCT OVERVIEW:
Preventing unsafe pressure and temperature buildup within water heating equipment is the primary function of a temperature and pressure relief valve. The Bradford White 415-33630-04 1" Temperature & Pressure Relief Valve 150 PSI serves as a dedicated safety component that automatically discharges water if internal tank conditions exceed set operational limits.

HYDROSTATIC DISCHARGE MECHANICS:
A temperature and pressure relief valve operates through dual internal sensing mechanisms that respond independently to excessive heat or pressure. When internal system pressure reaches 150 PSI or fluid temperature exceeds the thermal threshold, the valve spring mechanism unseats to vent water and relieve internal stress.

SYSTEM DEPRESSURIZATION:
A temperature and pressure relief valve acts as a primary protective barrier within the water heating circuit during excessive operating conditions. Automatically discharging high-temperature water allows cooler supply water to enter the vessel, reducing thermal energy and restoring safe internal operating pressures.

REPLACEMENT GUIDELINES:
Replace the Bradford White 415-33630-04 1" Temperature & Pressure Relief Valve when inspection identifies persistent leakage, corrosion, failure to open during testing, or failure to reseat after discharge. Verify the 150 PSI setting, connection size, temperature rating, and water heater requirements before installation. A qualified technician should perform replacement, and the relief discharge arrangement must comply with manufacturer instructions and applicable safety requirements.

COMMON FAILURE SYMPTOMS:

  • Persistent water dripping or leaking from the discharge line.
  • Corrosion or mineral buildup around the valve body or outlet threads.
  • Failure of the valve to seat properly after manual or automatic actuation.
  • Complete failure to discharge water during over-temperature or over-pressure conditions.

EQUIPMENT COMPATIBILITY:
The Bradford White 415-33630-04 temperature & pressure relief valve is an OEM component designed for select compatible systems. Verify the original part number, 1-inch connection, 150 PSI pressure setting, temperature rating, and complete water heater model against manufacturer documentation before purchase.

TECHNICAL SPECIFICATIONS:
Product identification:
Brand: Bradford White
Part Number: 415-33630-04
Product Type: Temperature & Pressure Relief Valve
Valve specifications:
Valve Function: Temperature and Pressure Relief
Pressure Setting: 150 PSI
Application: Water Heating Equipment
Connection specifications:
Connection Size: 1 Inch

Write Your Own Review
You're reviewing:Bradford White 415-33630-04 1" Temperature & Pressure Relief Valve 150 PSI
Your Rating
Customer Questions
What maintenance is required for the Bradford White 415-33630-04 Temperature & Pressure Relief Valve?

Periodically test the valve by lifting the lever to ensure it opens smoothly. Inspect for leaks, corrosion, or mineral buildup, and replace any worn components. Proper maintenance prevents unsafe pressure buildup and ensures accurate operation.

What are common issues with the Bradford White 415-33630-04 Temperature & Pressure Relief Valve?

  • Leaking around the valve seat.
  • Valve sticking or failing to open.
  • Corrosion or mineral buildup reducing performance.
  • Inconsistent pressure release.

How does the Bradford White 415-33630-04 Temperature & Pressure Relief Valve protect a water heater?

It provides pressure and temperature protection by releasing water when either condition reaches the valve's designated safety limit.

How does the Bradford White 415-33630-04 respond to excessive temperature or pressure?

It opens when the monitored temperature or pressure reaches its specified activation threshold, allowing hot water to discharge through the relief outlet.

Which water heater requirements should be evaluated when selecting the Bradford White 415-33630-04 as a replacement?

Consider the heater's approved relief-valve requirements, temperature and pressure ratings, connection arrangement, and discharge-pipe configuration against the equipment manufacturer's documentation.

What conditions can compromise the Bradford White 415-33630-04 Temperature & Pressure Relief Valve's operation?

Corrosion, mineral buildup, damaged sealing surfaces, or internal wear can interfere with proper relief activation and resealing.

What water heater conditions may indicate a problem with the Bradford White 415-33630-04?

Repeated discharge, continuous dripping from the relief outlet, visible leakage, or failure to release water when required may indicate a valve issue.

Installation Steps

Step 1: Turn off power and water supply for safety.

Step 2: Drain small amount of water to reduce pressure and access existing valve.

Step 3: Remove old valve with wrench and apply thread seal tape to new threads.

Step 4: Install new valve securely, ensuring proper alignment and tight sealing to prevent leaks.

Step 5: Restore water supply, check for leaks, and test discharge carefully; avoid hot water release.