The Robertshaw 41-205 Hot Surface Gas Range Ignitor is a high-quality 3-5/8” ignitor for gas ranges and HVAC systems. It operates by using a hot surface component to light the gas once the range is switched on allowing for a safe efficient startup. Being it used in gas ranges, ovens and HVAC heating systems, this ignitor provides reliable performance, long durability and quick ignition. The advantages of this product involve energy savings, increased safety and better consistency and reliable ignition.
https://www.partshnc.com/media/catalog/product/4/1/41-205.jpg
Manufacturer Name: Robertshaw
Product Number: 41-205
OEM Part Number: 41-205
Product Description: Hotsurfaceignitor,3 5/8"
Weight:0.34lbs/154.22g

Choose the best HVAC equipment parts and supplies from PartsHnC!

  • Same Day Shipping

  • Best Quality And Best Price

  • Wide Range of Inventory

  • Best Customer Service

Have More Questions or Need Help to Place The Order?
Reach us at (866)773-0907 or [email protected]

Write Your Own Review
You're reviewing:Robertshaw 41-205 Hot Surface Ignitor 3-5/8"
Your Rating
Customer Questions
What maintenance is required for the Robertshaw 41-205 Hot Surface Ignitor?

Inspect the ignitor element regularly for glazing, or brittle wear that can reduce heating efficiency and cause ignition failure. Ensure the ignitor is properly aligned within the burner assembly to avoid uneven heating pressure.

What are common issues with the Robertshaw 41-205 Hot Surface Ignitor?

  • Cracked or broken carbide element.
  • Ignitor failing to glow or heat fully.
  • Delayed ignition or weak startup performance.
  • Electrical resistance increase causing intermittent failure.
  • Damage from handling or thermal shock

Installation Steps

Step 1: Turn off power and gas supply to furnace, allow components to cool completely to prevent electric shock or burns.

Step 2: Remove access panel and disconnect old ignitor wiring carefully, noting placement.

Step 3: Unscrew and replace with new ignitor, avoiding direct contact with ceramic element.

Step 4: Reconnect wiring securely and reassemble panel.

Step 5: Restore power and test ignition cycle for proper operation, ensuring flame ignition.